Feasibility analysis of household electricity installation in Klambir V village Hamparan Perak district Deli Serdang regency
DOI:
https://doi.org/10.35335/mandiri.v11i4.193Keywords:
contact stop, electrical installation, groundingAbstract
Household electrical installations over time experience change both in quality and quantity. The declining quality of electrical installations and changes in the number of load points greatly affect the feasibility of electrical installations and the safety of the users. This research was conducted to know the percentage level of feasibility of household electrical installations and the factors that cause the infeasibility of household electrical installations. This research is a qualitative research study using a descriptive approach which was carried out in Klambir V Village, Hamparan Perak District, Deli Serdang Regency. The objects studied were 20 houses with the sampling technique used in this study used a random sampling technique. The instruments used were observation, interviews, and documentation. The data obtained from this study is the Percentage Level of household electrical installations in Klambir V Village, Hamparan Peraak District, Deli Serdang RegencyGround resistance value is still quite large and categorized as "not feasible" for a grounding system used by a building. soil content or soil resistance is still 7.91 ohms and the electrode rod uses 1 rod.
References
Alfith. (2013). Kelayakan instalasi listrik rumah tangga dengan pemakaian lebih dari 10 tahun di kanagarian nanggalo kecamatan koto xi tarusan kabupaten pesisir selatan. Jurnal Teknik Eletro ITP, Vol. 2 No.(2), 67.
Ali, muhamad hasan. (2013). Studi Kelayakan Instalasi Penerangan Rumah Di Atas Umur 15 Tahun Terhadap Puil 2000 Di Desa Pancur Kecamatan Pancur Kabupaten Rembang. Jurnal Teknik Elektro, 5(1), 49–52.
Anggito, A., & Setiawan, J. (2018). Metodologi Penelitian Kualitatif. CV. Jejak.
Apriyono, A. (2018). Tragis, Petani Tewas Tersengat Listrik Jebakan Tikus yang Dipasangnya Sendiri. Liputan6.Com. https://www.liputan6.com/regional/read/3690362/tragis-petani-tewas-tersengat-listrik-jebakan-tikus-yang-dipasangnya-sendiri
Aryamantara, K. J., Giriantari, I. A. ., & Sukerayasa, I. . (2018). Analisis Hubung Singkat Pada Jaringan Tegangan Menengah 20 kV Penyulang Kedonganan. Majalah Ilmiah Teknologi Elektro, 17(2), 213. https://doi.org/10.24843/mite.2018.v17i02.p08
Budi Santoso, D. H. (2016). Evaluasi Kelayakan Instalasi Listrik Rumah Tangga Dengan Pemakaian Lebih Dari 15 Tahun Berdasarkan Puil 2000 Di Desa Cipaku Kecamatan Cibogo Kabupaten Subang Jawa Barat. Program Stuniversitas Muhammadiyah Surakarta.
Herdianto, H. (2020). Deteksi Pencurian Arus Listrik pada Rumah Tangga Menggunakan Arduino Uno. InfoTekJar : Jurnal Nasional Informatika Dan Teknologi Jaringan, 4(2), 227–232. https://jurnal.uisu.ac.id/index.php/infotekjar/article/view/2421
Hidayat, A., & Harlanu, M. (2015). Kelayakan Instalasi Listrik Rumah Tangga Berdaya 900 VA Berumur di Atas 15 Tahun di Desa Bojonggede Kecamatan Ngampel Kabupaten Kendal. Jurnal Teknik Elektro Unnes, 7(1), 11–14.
Imran, A., Ruslan, & Syamsurijal. (2021). Analisis Gangguan Hubung Singkat pada Sistem Distribusi Tenaga Listrik UP3 Makassar Utara dengan Menggunakan Aplikasi Etap 12.6. Seminar Nasional Hasil Penelitian 2021, 1369–1377. https://www.etap.com
Indra, Z., & Ikhsan, K. (2011). Analisis Sistem Instalasi Listrik Rumah Tinggal dan Gedung untuk Mencegah Bahaya Kebakaran. Politeknik Negri Jakarta.
Instalasi Ketenagalistrikan, (2006).
Persyaratan Umum Instalasi Listrik 2000, 562 (2000).
Pardi, D. (2022). Analisis Load Flow dan Short Circuit serta Pengaruh Peletakan photovoltaic (PV) pada GI Kentungan Feeder KTN07. Electrices, 4(1), 12–17. https://doi.org/10.32722/ees.v4i1.4434
Samin, T. (2019). Analisa Gangguan Hubung Singkat Satu Fasa ke Tanah pada Jaringan Distribusi 20 KV PT. PLN (PERSERO) Sebatik menggunakan Software ETAP Power Station 12.6.0. Elektrika Borneo, 5(1), 19–24. https://doi.org/10.35334/jeb.v5i1.590
Saul B.P., O. (2021). Penentuan Arus Gangguan Hubung Singkat Sistem Khatulistiwa Pada Pt.Pln (Persero) Up3B Kalimantan Barat. Jurnal Teknik Elektro Universitas Tanjungpura, 2(1), 1–11.
Sony, A. (2016). Rumusan Metode Deteksi Pencurian Listrik Memanfaatkan Perangkat WSN. MIPA, 39(2), 107–114.
Sujito, S. (2009). Sistem Deteksi Hilang Daya Pada Gardu Trafo Tiang Jaringan Tegangan Rendah Pelanggan Pln. Tekno, 12(1), 62–75.
Syah, F. R. (2021). Analisis Hubung Singkat Pada Sistem Distribusi 20 Kv Pt. Pertamina Ep Asset 4 Field Cepu Distrik Ledok Menggunakan Etap 12.6.0. Jurnal Teknik Elektro, 10(3), 699–706.
Tukiman, Khairul Handono, A. S. (2017). Analisis arus hubung singkat pada sistem catu daya listrik iradiator gamma (Vol. 1).
Wibowo, Y. C. (2011). Tahanan Grounding Rumah Tinggal Di Kecamatan Gunungpati Kota Semarang. Universitas Negeri Semarang.
Wicaksono, P. (2016). Ini Cara PLN Deteksi Pencurian Listrik. Liputan6.Com. https://www.liputan6.com/bisnis/read/2453718/ini-cara-pln-deteksi-pencurian-listrik